Sumérgete en la imagen más completa hasta la fecha de los patrones de artroplastia de cadera y rodilla de EE. UU.

Immerse Yourself in the Most Comprehensive Picture to Date of U.S. Hip and Knee Arthroplasty Patterns

 

Fuente

Este artículo es publicado originalmente en:

http://connect.ajrr.net/2017-annual-report-download

 

De:

-Daniel J. Berry, MD
Chair, AJRR Board of Directors, 2014-2017

 

Todos los derechos reservados para:

 

© 2009-2017. American Joint Replacement Registry.

 

«This year marks an exciting milestone for the American Joint Replacement Registry (AJRR) – we have surpassed the one million mark in number of hip and knee arthroplasty procedures entered into the Registry. This accomplishment has been made possible by the nearly 1,000 hospitals, ambulatory surgery centers (ASCs), and practice groups who are Registry participants.

We are proud to present this 2017 Annual Report which reflects data collected from 2012 through 2016. The report includes data on 860,080 procedures from 654 institutions and 4,755 surgeons, representing a 101% increase in procedures, a 57% increase in reporting institutions, and a 50% increase in surgeons since last year’s report.»

 

Get the 2017 Annual Report now for:

  • Procedural and component data on primary and revision total joint replacement surgeries
  • 2016 and preliminary 2017 accomplishments
  • Information on AJRR’s collaborations, advocacy, and quality initiative efforts
  • Data from the former California Joint Replacement Registry (CJRR), which is now fully integrated into AJRR as the California State Registry
  • Special topics and additional insights

Slides of the individual figures and tables from the 2017 Annual Report can be downloaded on the AJRR website.

«Este año marca un hito emocionante para el American Joint Replacement Registry (AJRR): hemos superado la marca de un millón en procedimientos de artroplastia de cadera y rodilla inscritos en el Registro. Este logro ha sido posible gracias a los casi 1,000 hospitales ambulatorios centros de cirugía (ASC) y grupos de práctica que son participantes del Registro.
Estamos orgullosos de presentar este Informe Anual 2017 que refleja los datos recopilados desde 2012 hasta 2016. El informe incluye datos sobre 860,080 procedimientos de 654 instituciones y 4,755 cirujanos, lo que representa un aumento del 101% en los procedimientos, un aumento del 57% en las instituciones informantes y un Aumento del 50% en cirujanos desde el informe del año pasado «.

Obtenga ahora el Informe anual 2017 para:
Datos de procedimientos y componentes sobre cirugías de reemplazo total de articulaciones primarias y de revisión
2016 y logros preliminares de 2017
Información sobre colaboraciones de AJRR, defensa y esfuerzos de iniciativa de calidad
Datos del antiguo Registro de Reemplazo Articular de California (CJRR), que ahora está completamente integrado en AJRR como el Registro del Estado de California
Temas especiales y perspectivas adicionales
Las diapositivas de las figuras y tablas individuales del Informe Anual 2017 pueden descargarse en el sitio web de AJRR.

En nuestra muestra, las cabezas bipolares se utilizan en la mayoría de casos con los vástagos de la hemiartroplastia a partir de la edad 50-90, pero con una tendencia significativa hacia una mayor proporción de cabezas unipolar con cada década adicional de vida

 

La rotación externa de los componentes femorales afecta la biomecánica de la rodilla: un modelo computacional de la TKA estabilizada posteriormente.

Femoral Component External Rotation Affects #Knee Biomechanics: A Computational Model of Posterior-stabilized

 

 

Fuente

Este artículo es originalmente publicado en:

https://www.ncbi.nlm.nih.gov/pubmed/29529625

https://insights.ovid.com/crossref?an=00003086-201801000-00022

 

De:

 

Kia M1Wright TMCross MBMayman DJPearle ADSculco PKWestrich GHImhauser CW.

 2018 Jan;476(1):113-123. doi: 10.1007/s11999.0000000000000020.

 

Todos los derechos reservados para:

Copyright © 2017 Ovid Technologies, Inc., and its partners and affiliates. All Rights Reserved.
Some content from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.

 

 

Abstract

BACKGROUND:

The correct amount of external rotation of the femoral component during TKA is controversial because the resulting changes in biomechanical knee function associated with varying degrees of femoral component rotation are not well understood. We addressed this question using a computational model, which allowed us to isolate the biomechanical impact of geometric factors including bony shapes, location of ligament insertions, and implant size across three different knees after posterior-stabilized (PS) TKA.

QUESTIONS/PURPOSES:

Using a computational model of the tibiofemoral joint, we asked: (1) Does external rotation unload the medial collateral ligament (MCL) and what is the effect on lateral collateral ligament tension? (2) How does external rotation alter tibiofemoral contact loads and kinematics? (3) Does 3° external rotation relative to the posterior condylar axis align the component to the surgical transepicondylar axis (sTEA) and what anatomic factors of the femoral condyle explain variations in maximum MCL tension among knees?

CONCLUSIONS:

A larger ratio of distances from the femoral insertion of the MCL to the posterior and distal cuts may cause clinically relevant increases in both MCL tension and compartmental contact forces.

CLINICAL RELEVANCE:

To obtain more consistent ligament tensions through flexion, it may be important to locate the posterior and distal aspects of the femoral component with respect to the proximal insertion of the MCL such that a ratio of 1 is achieved.

 

 

Resumen

 

ANTECEDENTES:

La cantidad correcta de rotación externa del componente femoral durante la TKA es controvertida debido a que los cambios resultantes en la función biomecánica de la rodilla asociados con diversos grados de rotación del componente femoral no se conocen bien. Abordamos esta cuestión utilizando un modelo computacional que nos permitió aislar el impacto biomecánico de los factores geométricos, incluidas las formas óseas, la ubicación de las inserciones de los ligamentos y el tamaño del implante en tres rodillas diferentes después de una TKA estabilizada posteriormente (PS).

 

PREGUNTAS / PROPÓSITOS:

Utilizando un modelo computacional de la articulación tibiofemoral, preguntamos: (1) ¿La rotación externa descarga el ligamento colateral medial (LCM) y cuál es el efecto sobre la tensión del ligamento lateral colateral? (2) ¿Cómo altera la rotación externa las cargas de contacto tibiofemoral y la cinemática? (3) ¿La rotación externa de 3 ° con respecto al eje condilar posterior alinea el componente con el eje transepicondíleo quirúrgico (sTEA) y qué factores anatómicos del cóndilo femoral explican las variaciones en la tensión máxima de MCL entre las rodillas?

CONCLUSIONES:

Una mayor proporción de distancias desde la inserción femoral del MCL hasta los cortes posteriores y distales puede causar aumentos clínicamente relevantes tanto en la tensión del MCL como en las fuerzas de contacto compartimentales.

 

RELEVANCIA CLÍNICA:

Para obtener tensiones ligamentosas más consistentes a través de la flexión, puede ser importante localizar los aspectos posterior y distal del componente femoral con respecto a la inserción proximal del MCL de manera que se logre una relación de 1.

 

PMID: 29529625  DOI:  10.1007/s11999.0000000000000020